Best Underlayment for Laminate Flooring: Thickness and Types
For most floating laminate floors, the right underlayment is 2–3 mm closed-cell foam with a built-in vapour barrier on concrete, or 3 mm fibreboard on timber. Anything thicker than 5 mm voids the warranty on nearly every click-lock system.
Types compared
| Type | Thickness | Best for | Cost |
|---|---|---|---|
| Closed-cell foam | 2–3 mm | General use, budget | Low |
| Foam with vapour barrier | 2–3 mm | Concrete slabs | Low–mid |
| Fibreboard (wood fibre) | 3–5 mm | Timber subfloors, sound | Mid |
| Cork | 2–4 mm | Comfort, acoustics | Mid–high |
| Rubber | 2–3 mm | Sound isolation | High |
| Combination (foam + film) | 3 mm | Concrete, one-step install | Low–mid |
Match the underlayment to the subfloor
- Concrete: foam with a built-in vapour barrier. Tape every seam — a gap defeats the barrier.
- Timber (plywood or chipboard): 3 mm fibreboard for sound and slight leveling.
- Underfloor heating: 2 mm foam rated for heat transfer. Thick underlayment blocks heat and voids the heating warranty.
- Upper floors: acoustic underlayment if impact noise matters — check the IIC/ΔLw rating.
Why thickness is a trap
Laminate clicks together and floats. A soft, thick underlayment lets the joints flex with every footstep, and the locking edge eventually cracks. Manufacturers specify a maximum — commonly 3 mm foam or 5 mm fibreboard. Exceeding it is the single most common warranty void.
What to check before buying
- The laminate manufacturer’s maximum underlayment thickness — in the installation PDF, not the shop listing.
- Whether a vapour barrier is required (concrete: yes; timber: usually no).
- The sound rating if the room is above a bedroom.
- Whether it is rated for underfloor heating.
- Roll coverage versus room area — add 10%.
Installation notes
- Run underlayment perpendicular to the laminate planks.
- Butt seams, do not overlap — overlapping creates a ridge that telegraphs.
- Tape seams on concrete with the barrier’s own tape, never duct tape.
- Leave the laminate’s 8–10 mm expansion gap; the underlayment does not replace it.
Sound ratings explained
Two numbers appear on acoustic underlayment: IIC (impact insulation class) and ΔLw (the European equivalent). Higher is better. For an upstairs room above a bedroom, look for IIC 60+ or ΔLw 20+; building regulations in flats often specify a minimum, so check before buying.
Foam alone typically adds 10–15 IIC points. Fibreboard or rubber-cork blends add 20–25. No underlayment turns a timber floor into a concrete one — if impact noise is a serious problem, the ceiling below needs work too.
Installation mistakes that void warranties
- Overlapping seams. They create a ridge that flexes the click joint above it.
- No vapour barrier on concrete. Moisture reaches the laminate core from below.
- Using carpet underlay. Too soft; the joints open within months.
- Running it over a door threshold. The transition needs a solid base.
- Laying on an uneven subfloor. Underlayment does not level anything; 3 mm over 2 m must be fixed first.
Quick answers
Can I use carpet underlay under laminate? No — too soft, and it voids the warranty.
Do I need a vapour barrier on a ground-floor slab? Yes, unless the underlayment has one built in.
Does thicker underlayment feel better? Slightly, at the cost of joint life. 3 mm is the sensible compromise.
For the adhesive side of laminate work, see best glue for laminate flooring.